Pump-Down Controller

The Model 4052 Pump-Down Controller offers precise liquid level management for industrial applications. Its 4-20mA input and scalable output provide accurate process control. Integrated seal fail monitoring enhances system reliability by detecting potential pump issues proactively. Duplex pump alternation extends equipment lifespan and ensures continuous operation by distributing wear evenly across multiple pumps. The controller includes dual run-time meters for comprehensive operational tracking. RS-485/Modbus communications facilitate seamless integration into existing supervisory control systems, enabling remote monitoring and data acquisition. This unit is designed for consistent performance in demanding environments, supporting efficient and automated pump-down operations with minimal intervention. Its robust feature set contributes to optimized system uptime and reduced maintenance requirements, ensuring operational continuity and data visibility for critical infrastructure management.

Pump Down Ctrl

DOWNLOADS:

4052-15psi

Specifications

Feature4-20mA Input/Scalable Output
FeatureSeal Fail Monitoring
FeatureDuplex Pump Alternation
FeatureHand-Off-Auto Controls
FeatureDual Run-time Meters
FeatureRS-485/Modbus Communications
Input Voltage120VAC ± 10% 50/60Hz
Power Consumption8W
Signal Input4-20mA (optional 0-5V), 2 or 3 wire
Signal Input Load250 ohms
Dead Band1% of full scale
Repeat Accuracy± 1% of scaled (fixed conditions)
Display Type6 digit red LED display
Display Range (Level)00.0 to 346 ft
Display Range (Runtime)zero to 99,999.9 hours
Display Range (Delay)zero to 30 seconds
Display Resolution1 decimal place
Control Contacts4 SPDT 10A at 120VAC resistive
Power Loss Relay1 SPDT 5A at 120VAC resistive
Signal Output4-20mA, factory set to track input
Signal Output Load300 ohms
Probe Supply24VDC regulated
Setpoints3 levels, 2 alarms, all user-adjustable
Operating Temperature+14° to +122° F
Humidity Tolerance0-97% w/o condensation
Enclosure Material16 gauge steel
Terminationremovable terminal strips
Agency ApprovalsUL Recognized (U.S. & Canadian)
Panel Mount Cutout11.13" x 4.63"
Config: Probe Setting Options0-5, 0-10, 0-15, 0-20, 0-30, 0-40, 0-50, 0-60, 0-70, 0-80, 0-90, 0-100, 0-150 psi
Factory Setting (High Alarm)10.0 ft
Factory Setting (Level 2)8.0 ft
Factory Setting (Level 1)6.0 ft
Factory Setting (Pumps Off)4.0 ft
Factory Setting (Low Alarm)2.0 ft
Warranty1 year from date of manufacture

FAQs

What are the power requirements for the Model 4052 Pump-Down Controller?
The Model 4052 requires an input voltage of 120VAC ± 10% 50/60Hz, with a maximum power consumption of 8W.
What communication protocols does the Model 4052 support for system integration?
The controller supports RS-485/Modbus communications, allowing for integration into supervisory control systems.
What is the operational temperature range for the Model 4052 Pump-Down Controller?
The Model 4052 is designed to operate within a temperature range of +14° to +122° F.