Current Unbalance Detector

The Model 2722 Current Unbalance Detector provides essential monitoring for 3-phase AC current systems. This device ensures operational integrity by detecting current imbalances, which can indicate issues such as open heating elements or motor phase loss. With an adjustable unbalance trip point from 2% to 25% and a configurable trip delay from 0.2 to 20 seconds, it offers precise control. Its DPDT output contacts are rated for 10A at 240VAC resistive, providing robust switching capabilities. Designed for industrial environments, it operates reliably across a temperature range of -20° to +131° F, maintaining performance in diverse conditions. This unit supports both automatic and manual reset options, enhancing system flexibility. Its UL Recognized and CSA Certified status confirms adherence to industry standards, making it a dependable component for critical applications requiring consistent current monitoring and protection.

Ph Unbal Detector

DOWNLOADS:

a2722-24vac

Specifications

Input Voltage24VAC
Input Voltage Range20-28VAC
Power Consumption1.5W
VA Burden0.5VA per phase
Frequency Range50 - 400Hz
Current Range1 - 5 amps AC
Transient Protection2500V for 10ms
Unbalance Adjustment2% to 25%
Trip Delay0.2 to 20 seconds ± 5%
Output Contact FormDPDT
Output Contact Rating10A at 240VAC resistive
Expected Relay Life (Mechanical)10 million operations
Expected Relay Life (Electrical)100,000 at rated load
Operating Temperature-20° to +131° F
Humidity Tolerance0-97% w/o condensation
Enclosure MaterialABS plastic
Agency ApprovalUL Recognized
Agency ApprovalCSA Certified
FunctionMonitors 3-phase AC Current
FunctionCompares Three Single-phase Motors
FunctionDetects Open 3-phase Heating Element
Reset TypeAutomatic or Manual Reset

FAQs

What are the input voltage and frequency requirements for the A2722 Current Unbalance Detector?
The A2722 requires an input voltage of 24VAC, operating within a range of 20-28VAC. Its frequency range is 50 to 400Hz.
What is the adjustable range for current unbalance detection and trip delay on the Model 2722?
The Model 2722 offers an unbalance adjustment from 2% to 25%. The trip delay is adjustable from 0.2 to 20 seconds, with a tolerance of ± 5%.
What are the output contact specifications and expected lifespan of the A2722?
The A2722 features DPDT output contacts rated for 10A at 240VAC resistive. The expected mechanical relay life is 10 million operations, and electrical life is 100,000 operations at rated load.