Voltage Band Monitor

The Model 2681 Voltage Band Monitor offers essential protection for industrial systems. This device precisely monitors both over and under voltage conditions, safeguarding equipment from potential damage due to power fluctuations. Its automatic reset function ensures continuous operation without manual intervention after a voltage event, minimizing downtime. Available in both AC and DC versions, the 2681 accommodates diverse application requirements, supporting nominal voltages from 24vac to 240vac and 12vdc to 230vdc. With a robust SPDT output and a 10A contact rating at 240vac resistive, it provides reliable control for connected loads. The unit's compact design and wide operating temperature range from -20° to +122°F make it suitable for various industrial environments, contributing to system longevity and operational stability. Its set-point stability of ± 0.5% ensures consistent performance.

Voltage Band Mon

DOWNLOADS:

2681-208vac

Specifications

Output ConfigurationSPDT Output in Standard Relay Configuration
FunctionMonitors Over and Under Voltage
Available VersionsAC or DC
Reset TypeAutomatic Reset
Config: Nominal AC Voltage24vac, 120vac, 208vac, 240vac
Config: Max Input Voltage (AC)32vac, 160vac, 250vac, 285vac
Config: Under Voltage Range (AC)19-24vac, 90-120vac, 185-208vac, 200-240vac
Config: Over Voltage Range (AC)24-29vac, 120-150vac, 208-240vac, 240-270vac
Input Frequency (AC Models)50-400 Hz
Config: Nominal DC Voltage12vdc, 24vdc, 28vdc, 48vdc, 110vdc, 230vdc
Config: Max Input Voltage (DC)17vdc, 32vdc, 37vdc, 62vdc, 145vdc, 270vdc
Config: Under Voltage Range (DC)10-12vdc, 19-24vdc, 22-28vdc, 38-48vdc, 85-110vdc, 175-230vdc
Config: Over Voltage Range (DC)12-15vdc, 24-29vdc, 28-34vdc, 48-58vdc, 110-135vdc, 230-260vdc
Power Consumption2 watts max
Set-point Stability± 0.5% of set-point
Dead Band2%
Polarity ProtectionDC versions only
Trip Response0.5 sec fixed (± 0.1 sec)
Reset Time0.1 sec
Output ContactsSPDT
Contact Rating10A at 240vac resistive
Expected Relay Life, Mechanical10 million operations
Expected Relay Life, Electrical100,000 at rated load
Operating Temperature-20° to +122°F
Humidity Tolerance97% w/o condensation
Mounting8-pin socket (*order separately)
Case MaterialABS plastic
Dimension Tolerance± 0.06

FAQs

What is the primary function of the Model 2681 Voltage Band Monitor?
The Model 2681 monitors both over and under voltage conditions to protect connected equipment. It features an automatic reset.
What are the available voltage configurations for the Model 2681?
The Model 2681 is available in AC or DC versions. Nominal AC voltages include 24vac, 120vac, 208vac, 240vac. Nominal DC voltages include 12vdc, 24vdc, 28vdc, 48vdc, 110vdc, 230vdc.
What are the operating temperature range and output contact specifications?
The operating temperature range is -20° to +122°F. The output contacts are SPDT with a contact rating of 10A at 240vac resistive.