Model 2500 3-Phase Monitor

2500-480

The Model 2500 3-Phase Monitor provides essential protection for industrial systems. This device continuously monitors for critical conditions including phase loss, phase reversal, low voltage, and voltage unbalance. Its automatic reset feature ensures seamless operation following a fault correction, minimizing downtime. Equipped with heavy-duty output contacts, the Model 2500 offers robust control capabilities. The unit is UL Listed to U.S. and Canadian safety standards, affirming its reliability in demanding environments. With an adjustable trip delay from 1 to 10 seconds and a repeat accuracy of ±1% of full scale, it delivers precise and consistent performance. Available in multiple nominal AC voltage configurations, including 120V to 600V, it adapts to diverse applications. Its humidity tolerance of 0-97% without condensation further enhances its utility in varied industrial settings. This monitor is a dependable component for maintaining system integrity.

3Ph Monitor

DOWNLOADS:

2500-480

Specifications

Monitored ConditionsPhase Loss or Reversal, Low Voltage or Voltage Unbalance
Reset TypeAutomatic
Output Contacts FeatureHeavy Duty
Agency ApprovalUL Listed to U.S. and Canadian Safety Standards
Relay OperationWhen the correct voltage and phase sequence is applied, the output relay will not energize. An under voltage, phase reversal, phase unbalance or phase loss condition will cause the output relay to energize. Complete power loss will not cause a trip.
Config: Model Versions2500-120, 2500-208, 2500-240, 2500-380, 2500-415, 2500-480, 2500-600
Config: Nominal AC Voltage120, 208, 240, 380, 415, 480, 600
Config: Adjustment Range84-114V, 146-198V, 168-229V, 266-361V, 290-394V, 336-456V, 420-570V
Frequency50/60Hz
Unbalance Adjustment Range2 to 10% per NEMA specifications
Trip Delay Adjustment Range1 to 10 seconds (1 sec increments)
Power Consumption4.5W per phase
Repeat Accuracy±1% of full scale
Reset Time150ms nominal
Dead Band2% of full scale
Output ContactsSPDT 30 amps at 28VDC/300VAC 50/60Hz
Output Contacts (High Voltage)5 amps at 480/600VAC 50/60Hz 0.75 PF
Operating Temperature-4° to +131° F
Humidity Tolerance0-97% without condensation
Enclosure MaterialABS plastic
MountingSurface
Warranty5-year Unconditional Warranty

FAQs

What conditions does the Model 2500 3-Phase Monitor detect?
The Model 2500 detects phase loss or reversal, low voltage, and voltage unbalance conditions.
What are the specifications for the output contacts on the Model 2500?
The Model 2500 features SPDT output contacts rated for 30 amps at 28VDC/300VAC and 5 amps at 480/600VAC.
What is the operating temperature and humidity range for the Model 2500?
The Model 2500 operates from -4° to +131° F and tolerates 0-97% humidity without condensation.