Splash Pad Controller
The MODEL 36 Splash Pad Controller provides precise management for aquatic play features. With 12 individual outputs, it supports both Sequence and Random operating modes, allowing for diverse water activation patterns. Users can configure output timing with adjustable on/off controls, ranging from 120-300 seconds for activation and 1-30 seconds for deactivation. Remote start functionality, via 2-wire or 3-wire input, enhances operational flexibility. The unit's non-volatile memory retains all settings, ensuring consistent performance after power cycles. Custom programming options are available from the factory, tailoring the controller to specific project requirements. This robust design ensures reliable operation in various environmental conditions, with an operating temperature range of 0 to 130°F and 0-90% non-condensing humidity. Its 24VAC input and 12W power consumption offer efficient integration for demanding applications.
Pad Controller
Specifications
| Number of Outputs | 12 individual outputs |
|---|---|
| Output Options | 3 |
| Operating Modes | Sequence or Random |
| Time On/Off Control | Random or Adjustable |
| Start Type | Remote Start (2 wire or 3 wire) |
| Input voltage | 24VAC +/-10% |
| Power consumption | 12W |
| Signal input (trigger) | 2 wire / 3 wire |
| Display type | 7 segment LED / 17 LED's |
| Output | 12 relays (SPST) |
| Output configuration | See output setup |
| Surge protection | 1500W (10/1000 μs) |
| Circuit breaker | 500mA |
| Circuit breaker protection | Protects Model 36 only |
| Operating temp. | 0 - 130°F |
| Humidity | 0 - 90% non-condensing |
| Country of Origin | U.S.A. |
| Sequence Mode Operation | Once triggered, the unit will activate up to four outputs for a predetermined time, deactivate those outputs and then repeat with the next outputs in sequence. |
| Random Mode Operation | Once triggered, the unit will activate up to four outputs for a random amount of time (120 to 300 sec.). After that, the unit will deactivate those outputs (1 to 30 sec.), then pick a new set of outputs. |
| Customization | Custom programming is available from the factory. |
| Output Relay Option 1 | No jumper — The relay is a dry contact (SPST/N.O.) for that channel. |
| Output Relay Option 2 | Jumper center and upper pin - The relay will provide 24VAC to the output pin for that channel. |
| Output Relay Option 3 | Jumper center and lower pin - The relay will provide ground to the output pin for that channel. |
| Output Relay Contact Rating (VAC) | 10A @ 240VAC |
| Output Relay Contact Rating (VDC) | 3A @ 30VDC |
| Config: Control Function Position 1 | ON: Output in sequence; OFF: Output is random |
| Config: Control Function Position 2 | ON: Random time ON up to value set by pot; OFF: Exact time set by pot |
| Config: Number of outputs | 1 (Pos 3: OFF, Pos 4: OFF); 2 (Pos 3: ON, Pos 4: OFF); 3 (Pos 3: OFF, Pos 4: ON); 4 (Pos 3: ON, Pos 4: ON) |
| Output Enable/Disable | 12 position dip switch (Channels set to OFF are disabled) |
| Time Adjustment: Output ON time | 120 - 300 Sec. |
| Time Adjustment: Output OFF time | 1 - 30 Sec. |
| Time Adjustment: Run time | 5 - 30 Min. |
| Memory | All settings are stored in non-volatile memory. |
| Warranty | 1 year |