2742-115VAC

The Model 2742 3-Phase Over/Under Current Monitor provides essential protection for industrial systems. Its fail-safe design ensures operational integrity by continuously monitoring current levels. Users can configure the unit for either over or under current detection, adapting to specific application requirements. An adjustable trip delay, ranging from 0.2 to 20 seconds, allows for precise response timing, preventing nuisance trips while ensuring critical protection. The device supports both automatic and manual reset options, offering operational flexibility. With a DPDT contact configuration and a 10A contact rating at 240VAC resistive, it integrates effectively into control circuits. This monitor is suitable for applications involving motors, pumps, and conveyors, contributing to system reliability and minimizing downtime. Its robust construction and 10 million mechanical operations relay life ensure long-term performance.

The Model 2742 3-Phase Over/Under Current Monitor is designed to monitor
the current level of a 3-phase line or to compare the currents of three
single-phase lines. The Model 2742 is factory-set as an over-current
monitor; that is, if one or more current inputs rises above the trip
level, the internal relay will de-energize. Adding a wire between the
UNDER CURRENT terminals on the case will cause the Model 2742 to sense a
decrease of one or more current inputs. An adjustable trip delay of 0.2
to 20 seconds will prevent nuisance tripping. The current trip point is
adjustable from 1 to 5 amps, and matching current transformers are
available to extend the current range of the monitor. The Model 2742
will automatically reset when the current fault is corrected. An
external manual reset can be added by installing a normally closed
switch between the terminals marked RESET.

Out of stock

$630.00

Specifications

Supply voltage100-130VAC
Max supply voltage140V
Power consumption1.5 Watts
Transient protection2500 VRMS for 10ms
Frequency range50 - 400Hz
Input current1-5 amps ±5%
input current40 amps for 2 sec
Current range1-5 amps ± 5%
Trip delay0.2 to 20 sec ± 5%
Dead band4%
Contact ConfigurationDPDT
Contact Rating10A at 240VAC resistive
Expected relay life (Mechanical)10 million operations
Expected relay life (Electrical)100,000 ops at rated load
Operating temperature-20° to +131° F
Enclosure materialABS plastic
FunctionMonitors over or under current
DesignFail-safe design
Reset TypeAutomatic or manual reset
Trip Delay TimerAdjustable
Typical Applicationsmotors, pumps, conveyors, etc.

FAQs

What current range does the Model 2742 monitor?
The Model 2742 monitors input currents within a 1-5 amps range, detecting both over and under current conditions.
What are the power supply requirements and transient protection capabilities of this monitor?
The monitor operates on a 100-130VAC supply voltage and offers transient protection up to 2500 VRMS for 10ms.
What is the expected relay life and contact configuration of the Model 2742?
The relay has an expected mechanical life of 10 million operations and an electrical life of 100,000 operations at rated load. It features a DPDT contact configuration.