2742-115VAC
The Model 2742 3-Phase Over/Under Current Monitor provides essential protection for industrial systems. Its fail-safe design ensures operational integrity by continuously monitoring current levels. Users can configure the unit for either over or under current detection, adapting to specific application requirements. An adjustable trip delay, ranging from 0.2 to 20 seconds, allows for precise response timing, preventing nuisance trips while ensuring critical protection. The device supports both automatic and manual reset options, offering operational flexibility. With a DPDT contact configuration and a 10A contact rating at 240VAC resistive, it integrates effectively into control circuits. This monitor is suitable for applications involving motors, pumps, and conveyors, contributing to system reliability and minimizing downtime. Its robust construction and 10 million mechanical operations relay life ensure long-term performance.
The Model 2742 3-Phase Over/Under Current Monitor is designed to monitor
the current level of a 3-phase line or to compare the currents of three
single-phase lines. The Model 2742 is factory-set as an over-current
monitor; that is, if one or more current inputs rises above the trip
level, the internal relay will de-energize. Adding a wire between the
UNDER CURRENT terminals on the case will cause the Model 2742 to sense a
decrease of one or more current inputs. An adjustable trip delay of 0.2
to 20 seconds will prevent nuisance tripping. The current trip point is
adjustable from 1 to 5 amps, and matching current transformers are
available to extend the current range of the monitor. The Model 2742
will automatically reset when the current fault is corrected. An
external manual reset can be added by installing a normally closed
switch between the terminals marked RESET.
Out of stock
$630.00
Specifications
| Supply voltage | 100-130VAC |
|---|---|
| Max supply voltage | 140V |
| Power consumption | 1.5 Watts |
| Transient protection | 2500 VRMS for 10ms |
| Frequency range | 50 - 400Hz |
| Input current | 1-5 amps ±5% |
| input current | 40 amps for 2 sec |
| Current range | 1-5 amps ± 5% |
| Trip delay | 0.2 to 20 sec ± 5% |
| Dead band | 4% |
| Contact Configuration | DPDT |
| Contact Rating | 10A at 240VAC resistive |
| Expected relay life (Mechanical) | 10 million operations |
| Expected relay life (Electrical) | 100,000 ops at rated load |
| Operating temperature | -20° to +131° F |
| Enclosure material | ABS plastic |
| Function | Monitors over or under current |
| Design | Fail-safe design |
| Reset Type | Automatic or manual reset |
| Trip Delay Timer | Adjustable |
| Typical Applications | motors, pumps, conveyors, etc. |