3-Phase Monitor

2500D-120

The 2500D 3-Phase Monitor provides essential protection for industrial systems. This device continuously monitors for critical conditions including phase loss, phase reversal, low voltage, and voltage unbalance. Its automatic reset feature simplifies operation, ensuring minimal downtime following a transient event. The monitor's robust DPDT output contacts are rated for 10 amps at 28VDC/300VAC, accommodating diverse control circuit requirements. With configurable nominal AC voltages spanning 120V to 600V, the 2500D integrates into various electrical infrastructures. A trip delay adjustment range of 1 to 10 seconds allows for precise response tuning. Power consumption is 4.5W per phase. Designed for surface mounting, its ABS plastic enclosure ensures durability across an operating temperature range of -4° to +131° F. The unit's ability to not trip on complete power loss enhances system stability. UL listing confirms adherence to safety standards.

3Ph Monitor

DOWNLOADS:

2500d-120

Specifications

Monitored ConditionsPhase Loss or Reversal, Low Voltage or Voltage Unbalance
Reset TypeAutomatic
Output ContactsHeavy Duty DPDT
OperationOn a fault condition (under voltage, phase reversal, unbalance, or loss), the output relay energizes. The relay will not energize on correct voltage/phase sequence.
Power Loss BehaviorComplete power loss will not cause Model 2500D to trip.
Config: Model Suffix-120, -208, -240, -380, -415, -480, -600
Config: Nominal AC Voltage120, 208, 240, 380, 415, 480, 600
Config: Adjustment Range84-114V, 146-198V, 168-229V, 266-361V, 290-394V, 336-456V, 420-570V
Frequency50/60Hz
Unbalance Adjustment Range2 to 10% per NEMA specifications
Trip Delay Adjustment Range1 to 10 seconds (1 second increments)
Power Consumption4.5W per phase
Repeat Accuracy±1% of full scale
Reset Time150ms nominal
Dead Band2% of full scale
Output Contact RatingDPDT 10 amps at 28VDC/300VAC 50/60Hz; 5 amps at 480/600VAC 50/60Hz
Operating Temperature-4° to +131° F
Humidity Tolerance0-97% without condensation
Enclosure MaterialABS plastic
MountingSurface
Agency ApprovalUL Listed to U.S. and Canadian safety standards
Warranty5-year Unconditional Warranty

FAQs

How does the 2500D handle power interruptions?
The 2500D is designed not to trip on a complete power loss, maintaining system stability. It also features an automatic reset type.
What voltage conditions does the 2500D monitor?
The 2500D monitors for phase loss, phase reversal, low voltage, and voltage unbalance across nominal AC voltages from 120V to 600V.
What are the output contact specifications for the 2500D?
The 2500D utilizes heavy-duty DPDT output contacts, rated for 10 amps at 28VDC/300VAC and 5 amps at 480/600VAC.