22LM

22LM

The 22-LM 3-Phase Monitor provides essential protection for industrial systems, ensuring operational continuity and equipment longevity. Its adjustable trip delay, ranging from 1 to 30 seconds for voltage and unbalance faults, allows for precise system response customization, preventing unnecessary shutdowns while safeguarding machinery. A configurable restart delay, from 1 to 500 seconds, further enhances operational control by managing system re-engagement after a fault condition, reducing potential stress on motors and other components. This unit features a manual reset, ensuring deliberate system re-engagement only when conditions are verified safe. With an operating voltage of 95-120 VAC and NEMA-compliant voltage unbalance trip settings, it offers robust and adaptable performance across various three-phase applications. The 5-year unconditional warranty underscores its reliability, making it a dependable component for critical industrial infrastructure.

A microcontroller-based universal 3-phase monitor for protecting 3-phase
motors from abnormal power conditions. It can detect under voltage, over
voltage, voltage unbalance, reverse phase, and single-phasing even when
regenerated voltage is present. The Model 22 includes adjustable trip
and restart delays to prevent nuisance tripping during power
fluctuations and short cycling in compressor applications. The LED
status indicators and adjustment pots for Voltage Adjustment, %
Unbalance, Restart Delay and Trip Delay are mounted on the front of the
unit for easy access along with 2 SPDT relay contacts. Automatic or
manual restart versions are available. The Model 22 does not require a
neutral connection and can be used on either Wye or Delta systems.

Out of stock

$294.00

Specifications

Reset TypeManual Reset
Operating Voltage95-120 VAC
Power Consumption6W at 120V
Auto RangesNo
Frequency50/60Hz
Type of MeasurementRMS
Under Voltage Trip90% ±1% (% of setpoint)
Under Voltage Reset93% ±1% (% of setpoint)
Over Voltage Trip110% ±1% (% of setpoint)
Over Voltage Reset107% ±1% (% of setpoint)
Voltage Unbalance Trip2-8%, adjustable (conforms to NEMA)
Voltage Unbalance ResetTrip setting minus 0.7%
Trip Delay (Voltage/Unbalance Faults)1-30 sec., adjustable
Trip Delay (Single-Phasing Faults)1 sec., fixed
Trip Delay (Unbalance > 15%)1 sec., fixed
Restart Delay1-500 sec., adjustable
Manual Reset Input5V open circuit/500µA short circuit
Manual Reset RequirementExternal N.O. momentary pushbutton required
Output Contacts2X SPDT 10A at 240VAC resistive
Operating Temperature-20° to +140° F
Humidity Tolerance0-97% w/o condensation
Terminal Torque (Power and Relay)9 in lbs max
Terminal Torque (Manual Reset)5.3 in lbs max
Wire Type (Power and Relay)12-22 AWG
Wire Type (Manual Reset)12-30 AWG
EnclosureNoryl plastic
MountingSurface Mount
Additional Options/SG = Silver with Gold Flash Contacts
System CompatibilityWye or Delta systems
Neutral ConnectionNot required
Dimension Tolerance± 0.06 in
Mounting Hole Diameter0.25 in
Warranty5-year Unconditional Warranty

FAQs

How is the 22-LM 3-Phase Monitor reset after a fault condition?
The 22-LM features a Manual Reset type. It requires an external N.O. momentary pushbutton for system re-engagement following a trip event.
What is the operating voltage range for the 22-LM monitor?
The 22-LM 3-Phase Monitor operates within a 95-120 VAC range, suitable for specific industrial power configurations.
Can the trip and restart delays be adjusted on the 22-LM unit?
Yes, the 22-LM offers adjustable delays. The Trip Delay for voltage and unbalance faults can be set from 1-30 seconds, and the Restart Delay is adjustable from 1-500 seconds.