3-Phase Monitor with Adjustable Trip & Restart Delays

22L

The 22-L 3-Phase Monitor provides essential protection for industrial systems. Its adjustable trip delay, ranging from 1 to 30 seconds, allows for precise response to voltage and unbalance faults, preventing unnecessary shutdowns while ensuring critical protection. A configurable restart delay, from 1 to 500 seconds, supports controlled system re-engagement after a fault, minimizing abrupt restarts and potential stress on machinery. This unit monitors for under voltage, over voltage, and voltage unbalance, with unbalance trip settings adjustable from 2-8% conforming to NEMA standards. With auto reset functionality and robust 2X SPDT 10A output contacts, it integrates seamlessly into various control schemes. This monitor enhances operational stability, reduces downtime, and contributes to extended equipment longevity by maintaining optimal electrical conditions and offering precise fault management.

Dpdt 120V Universal 3-Ph

DOWNLOADS:

22l

Specifications

Reset TypeAuto Reset
Operating Voltage95-120 VAC
Power Consumption6W at 120V
Auto RangesNo
Frequency50/60Hz
Type of MeasurementRMS
Under Voltage Trip90% ±1% (% of setpoint)
Under Voltage Reset93% ±1% (% of setpoint)
Over Voltage Trip110% ±1% (% of setpoint)
Over Voltage Reset107% ±1% (% of setpoint)
Voltage Unbalance Trip2-8%, adjustable (conforms to NEMA)
Voltage Unbalance ResetTrip setting minus 0.7%
Trip Delay (Voltage/Unbalance Faults)1-30 sec., adjustable
Trip Delay (Single-Phasing Faults)1 sec., fixed
Trip Delay (Unbalance > 15%)1 sec., fixed
Restart Delay1-500 sec., adjustable
Manual Reset Input5V open circuit/500µA short circuit
Output Contacts2X SPDT 10A at 240VAC resistive
Operating Temperature-20° to +140° F
Humidity Tolerance0-97% w/o condensation
Terminal Torque (Power and Relay)9 in lbs max
Terminal Torque (Manual Reset)5.3 in lbs max
Wire Type (Power and Relay)12-22 AWG
Wire Type (Manual Reset)12-30 AWG
EnclosureNoryl plastic
MountingSurface Mount
Additional Options/SG = Silver with Gold Flash Contacts
System CompatibilityWye or Delta systems
Neutral ConnectionNot required
Dimension Tolerance± 0.06 in
Mounting Hole Diameter0.25 in
Warranty5-year Unconditional Warranty

FAQs

What is the operating voltage range for the 22-L 3-Phase Monitor?
The 22-L operates within a 95-120 VAC range at 50/60Hz.
Can the trip and restart delays be adjusted on this monitor?
Yes, the trip delay for voltage/unbalance faults is adjustable from 1-30 seconds, and the restart delay is adjustable from 1-500 seconds.
What type of output contacts does the 22-L monitor utilize?
It features 2X SPDT 10A at 240VAC resistive output contacts.