3-Phase Monitor with Adjustable Trip & Restart Delays

20AB-H/SG

The Model 20AB-H 3-Phase Monitor provides essential protection for industrial systems. Its adjustable trip delay, ranging from 1-30 seconds, allows for precise response to detected anomalies, preventing premature shutdowns. The adjustable restart delay, from 1-500 seconds, facilitates controlled system re-engagement after a fault, optimizing operational continuity. This device comprehensively monitors critical conditions including phase loss, phase reversal, over/under voltage, and voltage unbalance, ensuring robust system integrity. With an operating voltage of 475-600 VAC and an auto-reset function, it minimizes manual intervention and reduces potential downtime. The unit's robust design, featuring a Noryl plastic enclosure, contributes to its reliability across diverse operating environments, from -20° to +140° F. It offers a utility-focused solution for maintaining consistent three-phase power integrity and safeguarding connected equipment.

Unv 3Ph Monitor

DOWNLOADS:

20ab-h-sg

Specifications

Reset TypeAuto Reset
Operating Voltage475-600 VAC
Power Consumption4.5W at 600V
Auto RangesNo
Monitored ConditionsPhase Loss, Phase Reversal, Over/Under Voltage and Voltage Unbalance
Frequency50/60Hz
Type of MeasurementRMS
Under Voltage Trip90% ±1% (% of setpoint)
Under Voltage Reset93% ±1% (% of setpoint)
Over Voltage Trip110% ±1% (% of setpoint)
Over Voltage Reset107% ±1% (% of setpoint)
Voltage Unbalance Trip2-8%, adjustable (conforms to NEMA)
Voltage Unbalance ResetTrip setting minus 0.7%
Trip Delay Time (Over, Under, & Unbalanced)1-30 sec., adjustable
Trip Delay Time (Single-Phasing Faults)1 sec., fixed
Trip Delay Time (Unbalance > 15%)1 sec., fixed
Restart Delay1-500 sec., adjustable
Manual Reset Input5V open circuit/500µA short circuit
Output Contacts1x N.C., 1x N.O. 7.5A at 240VAC resistive
Operating Temperature-20° to +140° F
Humidity Tolerance0-97% w/o condensation
Terminal Torque3.5 in. lbs. maximum
Wire TypeStranded or solid 14-26 AWG, 1/terminal
Enclosure MaterialNoryl plastic
MountingDIN Rail or Surface Mount
Additional Options/SG = Silver with Gold Flash Contacts
Warranty5-year Unconditional Warranty

FAQs

What voltage range does the 20AB-H monitor and what conditions does it detect?
The 20AB-H monitors 3-phase systems within a 475-600 VAC operating voltage. It detects phase loss, phase reversal, over/under voltage, and voltage unbalance.
Are the trip and restart delays adjustable on the 20AB-H monitor?
Yes, the trip delay for over, under, and unbalanced conditions is adjustable from 1-30 seconds. The restart delay is adjustable from 1-500 seconds.
What type of output contacts does the 20AB-H provide and what is its reset mechanism?
The 20AB-H provides 1x N.C. and 1x N.O. output contacts, rated at 7.5A at 240VAC resistive. It features an auto-reset type.