3-Phase Voltage Unbalance Monitor

2002Y-69/120

The MODEL 2002Y 3-Phase Voltage Unbalance Monitor provides essential protection for industrial systems. It detects voltage imbalances across three phases, preventing potential equipment damage and operational disruptions. With an adjustable unbalance threshold from 2% to 10% and a rapid 150ms response time, it ensures timely intervention. The unit operates across a 50Hz-60Hz frequency range and accommodates various phase-neutral and phase-phase voltage configurations up to 480VAC. Its DPDT contact configuration and 10 amp at 240VAC resistive contact rating offer reliable control for connected equipment. Designed for surface mounting, its ABS plastic enclosure ensures durability in diverse environments. The monitor features automatic reset and an adjustable dropout time from 1 to 20 seconds, enhancing operational flexibility. A 5-year unconditional warranty underscores its robust design and long-term performance, minimizing maintenance concerns.

3Ph Unbal Mon

DOWNLOADS:

2002y-69-120

Specifications

Config: Model2002Y-69/120, 2002Y-120/208, 2002Y-138/240, 2002Y-220/380, 2002Y-240/415, 2002Y-277/480
Config: Phase-Neutral Voltage69VAC, 120VAC, 138VAC, 220VAC, 240VAC, 277VAC
Config: Phase-Phase Voltage120VAC, 208VAC, 240VAC, 380VAC, 415VAC, 480VAC
Connection TypeWye Connections
Voltage Range± 15%
Frequency50Hz-60Hz
Power Consumption (per phase max)2.0W
Transient Protection2500VRMS for 10ms
Repeat Accuracy± 0.1% (fixed conditions)
Unbalance Adjustment2% to 10%
Response Time150ms
Reset TimeFixed 1 sec
Dropout TimeAdjustable 1 to 20 seconds
Reset TypeAutomatic
Dead Band0.5% max
Contact ConfigurationDPDT
Contact Rating10 amps at 240VAC resistive
Expected Relay Life (Mechanical)10 million operations
Expected Relay Life (Electrical)100,000 operations at rated load
Operating Temperature-20° to +131° F
Humidity Tolerance0-97% w/o condensation
MountingSurface
Enclosure MaterialABS plastic
Mounting Hole Diameter0.19 in
Warranty5-year Unconditional Warranty

FAQs

What voltage configurations does the 2002Y monitor support?
The 2002Y supports phase-neutral voltages including 69VAC, 120VAC, 138VAC, 220VAC, 240VAC, and 277VAC. It also handles phase-phase voltages such as 120VAC, 208VAC, 240VAC, 380VAC, 415VAC, and 480VAC.
What is the adjustable unbalance range and response time for the 2002Y monitor?
The 2002Y monitor features an unbalance adjustment range from 2% to 10%. Its response time to detected unbalance conditions is 150ms.
What are the environmental operating specifications for the 2002Y monitor?
The 2002Y operates within a temperature range of -20° to +131° F. It tolerates humidity levels from 0-97% without condensation.