3-Phase Monitor

The Model 158 3-Phase Monitor provides essential protection for industrial systems. It continuously monitors for phase loss, low voltage, and phase reversal, safeguarding critical equipment from potential damage. Compatible with both Wye and Delta systems, this monitor does not require a neutral connection, simplifying installation procedures. Its automatic reset function minimizes downtime following a fault, while a rapid 0.5-second response time ensures prompt fault detection. The device offers robust transient protection up to 2500 VRMS for 10ms and maintains a repeat accuracy of ± 0.1% of setpoint under fixed conditions. Mounting options include DIN Rail or surface mount, providing installation flexibility. A 5-year unconditional warranty underscores its reliability, making it a dependable choice for maintaining operational integrity across diverse industrial applications.

Specifications

Config: ModelB158B, 158B, A158B, EX158B
Config: Input Voltage120VAC (B158B), 208/240VAC (158B), 480VAC (A158B), 380VAC (EX158B)
Config: Adjustment Range85-125VAC (B158B), 160-260VAC (158B), 380-500VAC (A158B), 300-400VAC (EX158B)
Config: Frequency60Hz (B158B, 158B, A158B), 50Hz (EX158B)
Config: Power Consumption (per phase).25W (B158B), .5W (158B), 1.5W (A158B), 1.25W (EX158B)
Config: SuffixR (for 5 minute time delay option)
MountingDIN Rail or Surface Mount
Monitored ConditionsPhase Loss, Low Voltage, Phase Reversal
Warranty5 Year Unconditional Warranty
System CompatibilityWye or Delta systems
Neutral ConnectionNot required
IndicatorFront-mounted LED failure indicator
Indicator (R Version)Additional LED indicator for RESTART
Transient Protection2500 VRMS of 10ms
Repeat Accuracy± 0.1% of setpoint (fixed conditions)
Response Time0.5 seconds
Reset TimeShort cycle restart delay - 2 seconds
Reset Time (R Version)5 minutes
Reset TypeAutomatic
Dead Band2%
Output ContactsSPDT
Contact Rating10A at 240VAC resistive
Expected Relay Life (Mechanical)10 million operations
Expected Relay Life (Electrical)100,000 operations at rated load
Operating Temperature-20° to +131° F
Humidity Tolerance97% w/o condensation
Enclosure MaterialABS plastic

FAQs

What conditions does the Model 158 monitor for?
The Model 158 monitors for phase loss, low voltage, and phase reversal.
What are the available input voltage configurations for the Model 158?
The Model 158 supports input voltages including 120VAC, 208/240VAC, 480VAC, and 380VAC, depending on the specific model variant.
Can the Model 158 be used in both Wye and Delta systems?
Yes, the Model 158 is compatible with both Wye and Delta systems and does not require a neutral connection.